Integrated control of dynamic facades and distributed energy resources for energy cost minimization in commercial buildings

Publication Type

Journal Article

Date Published

12/2015

Authors

Lee, Eleanor S., Christoph Gehbauer, Brian E. Coffey, Andrew McNeil, Michael Stadler, Chris Marnay

DOI

10.1016/j.solener.2015.11.003(link is external)

Abstract

Controllable window, shading, and daylighting technologies provide an interesting opportunity to manage end use demands on distributed energy resources (DER) in ways that both complements the peak output profile of solar photovoltaic (PV) electricity generation and counteracts the peak demands on the utility grid produced by daytime commercial activities. The objective of this study is to explore whether dynamic facade technologies can play an enabling role in supporting a desired level of electricity service at either minimum operating cost or minimum carbon footprint through optimized integrated control with distributed energy resources. A proof-of-concept control system was developed by approximating non-linearities as piecewise-linear and determining the control state of both the demand and supply side components through global optimization. Annual simulations of a south-facing office zone with switchable electrochromic windows, solar photovoltaic electricity generation, and battery storage indicated that with optimized integrated demand–supply side controls, the utility grid load profile could be lowered to nearly zero demand (5 W/m2) during the daytime when energy costs are highest. A full-scale outdoor field test in Berkeley, California verified this performance, demonstrating that during a week of sunny winter weather, electricity bills could be reduced by 63% compared to heuristic control of electrochromic windows without the photovoltaics and electrical storage. In both the simulated and measured cases, the photovoltaic system was sized to meet the peak perimeter zone load and the electrical storage was sized to be fully discharged by the end of the peak day. Technical and market challenges for achieving reliable optimal control for widespread applications are discussed.

Journal

Solar Energy

Volume

122

Year of Publication

2015

Organization

Building Technology and Urban Systems Division, Building Technologies Department, Windows and Envelope Materials, Energy Storage and Distributed Resources Division, Grid Integration Group, Energy Analysis and Environmental Impacts Division, International Energy Analysis Department, , CERCBEE

Research Areas

Microgrids, Windows and Daylighting, BTUS Windows and Daylighting, , EAEI Healthy & Efficient Buildings

Related Files

PDF (805.88 KB) (link is external)

        

©2025 Energy Technologies Area, Berkeley Lab
Lawrence Berkeley National Laboratory (link is external)
  • twitter(link is external)
  • instagram(link is external)
  • LinkedIn(link is external)
  • facebook(link is external)
  • youtube(link is external)
  • DOE logo
  • UC logo
A U.S. Department of Energy National Laboratory Managed by the University of California
Questions & Comments(link is external) Privacy & Security Notice(link is external)